Site icon Project Management 123

Method Statement For Painting Works

All painting works shall be carried out strictly in accordance with approved paint manufacturer’s recommendations and relevant applicable standards.

Application of Painting system to the internal/external surfaces shall be as approved by the CONSULTANT and as required in compliance with manufacturer’s recommendations, approved method statement, drawings and project specifications.

Method Statement For Painting Works

Test Area / Mock up Preparation:

Prior to start of mass application of painting system, mock-up will be done on site for each type of paint system for CONSULTANT approval.

All the paintwork will be done according to the Project Specifications and Manufacturer’s recommendations. Approved Mock up shall be retained until completion of works to serve as a standard for similar works through the building.

If it is requested by the CONSULTANT, manufacturer’s site visit will be arranged to ensure that the work is being carried out as per recommendations and quality is within acceptable range and will submit visit report.

Paint System with Area / Location of Use:

Washable Emulsion Paint System for Internal Plastered Walls

(Fenomastic Pure Color Emulsion Matt & Silk)

Washable Emulsion Paint System  for Internal Plastered Soffits and Ceiling

(Fenomastic Pure Color Emulsion Matt)

Pure Acrylic Paint System for Internal Plastered, Concrete and Gypsum Board Walls

(Jotashield top coat silk) in place of alkyd enamel paint system

Pure Acrylic Paint System for Internal Plastered, Concrete and Gypsum Board Ceiling

(Jotashield top coat matt) ) in place of alkyd enamel paint system

Epoxy Paint System to External Facades and Inside area of Parapet

(Penguard Texo & hardtop xp)

Paint System for Anti Bacterial and Anti Fungal Paint

(Fenomastic Hygiene Emulsion Matt)

Epoxy Paint System for Walls

(Penguard Texo)

Method Statement For Painting Works – Application Procedure:

Washable Emulsion Paint System for Internal Plastered Walls

(Fenomastic Pure Color Emulsion Matt & Silk)

Primer: 1 Coat

Stucco: 2 Coats

Fenomastic Pure Colours Emulsion Silk: 2 Coats

Washable Emulsion Paint System for Internal Plastered Soffits and Ceiling

(Fenomastic Pure Color Emulsion Matt)

Primer: 1 Coat

Stucco: 2 Coats

Fenomastic Pure Colours Emulsion Matt: 2 Coat

Pure Acrylic Paint System for Internal Plastered, Concrete and Gypsum Board Walls

(Jotashield top coat silk) in place of alkyd enamel paint system

Fenomastic  Emulsion Primer: 1 Coat

Stucco: 2 Coats

Jotashield Top Coat Silk: 2 Coat

Pure Acrylic Paint System for Internal Plastered, Concrete and Gypsum Board Ceiling

(Jotashield top coat silk) in place of alkyd enamel paint system

Fenomastic  Emulsion Primer: 1 Coat

Stucco: 2 Coats

Jotashield Top Coat Matt: 2 Coat

Epoxy Paint System to External Facades and Inside area of Parapet

(Penguard Texo & hardtop xp)

Penguard Clear Sealer             : 1 Coat

Penguard HB                             : 1 Coats

Penguard Texo                          : 1 Coat

Hardtop XP                                : 2 Coat

SURFACE PREPARATION

The substrate must be sound, clean, dry, free from dust, oil, grease and laitance etc from well cured and dry concrete / plaster surface, manually with rubbing stone, scrapper and sand paper etc.

SEALER COAT

Apply Penguard Clear Sealer (A+B) base and hardener mixed in ratio 4:1 thoroughly (may be diluted by Thinner No. 17, from 15 to 20% but without reducing the hiding properties) by roller and allow to cure for minimum 2 – 4 hours.

PRIMER COAT

Apply Penguard HB (A+B) base and hardener mixed in ratio 4:1 thoroughly (may be diluted by Thinner No. 17, around 10% but without reducing the hiding properties) by roller and allow to cure for minimum 4 – 8 hours.

TEXTURE COAT

Apply Penguard Texo (A+B) base and hardener mixed in ratio 4:1 thoroughly (may be slightly diluted by Thinner No. 17to a level so as to attain the required texture) and apply by spray gun and allow to cure for minimum 12 – 36 hours.

(Roll with a plastic roller dipped in thinner No. 2 or Kerosene prior to curing for a pressed pattern)

TOPCOATS

Apply 1st coat of Hardtop XP (A+B) base and hardener mixed in ratio 10:1 thoroughly (may be diluted 5 – 10% with Thinner No. 10, but without reducing the hiding properties) by roller and allow to cure for minimum 4 – 7 hours.

Apply 2nd Coat of Hardtop XP as above.

Paint System for Anti Bacterial and Anti Fungal Paint

(Fenomastic Hygiene Emulsion Matt)

P.V.A. Primer:     1 Coat

Fenomastic Hygiene Emulsion Matt:     2 Coats

SURFACE PREPARATION

The substrate must be sound, clean, dry, free from dust, oil, grease and laitance etc from well cured and dry concrete / plaster surface, manually with rubbing stone, scrapper and sand paper etc.

 PRIMER COAT

Apply P.V.A. Primer (5-10% diluted with fresh water, if required) by roller and allow drying for minimum 1 hour.

 FIRST TOP COAT:

Apply 1st coat of Fenomastic Hygiene Emulsion Matt by roller (may be diluted 5-10% with fresh water, but not to the extent of reducing the hiding properties) and allow to dry for min 4 hrs.

 SECOND TOP COAT:

Apply final coat of Fenomastic Hygiene Emulsion Matt as above.

Epoxy Paint System for Walls

(Penguard HB)

Penguard HB                              : 1 Coat

Penguard Texo Touch Up        :  (if required)

Penguard Topcoat                    : 2 Coats

SURFACE PREPARATION

The substrate must be sound, clean, dry, free from dust, oil, grease and laitance etc from well cured and dry concrete / plaster surface, manually with rubbing stone, scrapper and sand paper etc.

PRIMER COAT

Apply Penguard HB (A+B) base and hardener mixed in ratio 4: 1 thoroughly (may be slightly diluted by Thinner No. 17 but without reducing the hiding properties) and apply by spray and allow to dry for minimum 8 hours.

TEXTURE COAT

Touchup with Penguard Texo required place (A+B) base and hardener mixed in ratio 4: 1 thoroughly on the areas requiring filling and smoothening (may be slightly diluted by Thinner No. 17) and apply on the areas requiring filling and smoothening by scraper and allow to dry for minimum 8 hours.

FIRST TOPCPAT

Apply 1st coat of Penguard Topcoat (A + 8) base and hardener mixed in ratio 4: 1 thoroughly (may be diluted 5 to 10% with Thinner No. 10 (but without reducing the hiding properties) by roller and allow to cure for minimum 8 hours.

SECOND TOPCOAT

Apply the final coat of Penguard Topcoat as above.

Cleaning and Protection:

Adjacent surfaces of doors/window frames along with their fittings, lighting fixtures and other similar items as required, shall be protected. Polythene sheet may also be used to wrap the door or window leafs/glass when they are already installed.

Exit mobile version